PERFORMANCE
Accuracy: +/-0.001" or +/-0.1% of the distance from the transducer to the target surface, whichever is greater.
Repeatability:+/-0.05% of the distance from the transducer to the target
Inspection Rate: Variable to 125 measurements per second
Operating Range: 0.2" - 23.999" or 5mm - 609mm (Transducer to target)
Off-Axis Alignment: +/- 2.5 to 5 degrees depending on target size, material and range
ELECTRICAL
Input Power:
100 VAC, 50/60 Hz
120 VAC, 60 Hz
230 VAC, 50 Hz
Maximum Power Consumption: 35 watts
Standard Interfaces: Full duplex asynchronous RS-232C, 3-wire or RS-422A, 5-wire communications interface
Baud Settings: 300, 600, 1200, 2400, 4800, 9600, 19200, none
Word Length: 8 bit; 7 ASCII + 1 Parity Bit
Parity: unused
Stop Bit: 1 stop bit
Line Status: disable
16 bit parallel binary output, TTL Compatible 3mA Source, 20mA Sink
Optional Interface:
Analog: 0-10 VDC or 4-20mA (up to 2500 Ohm load for 4-20mA) Selectable analog span: 00.00" to 23.9999" or 0mm to 609mm in incremental steps of voltage or current within span: 4096 steps
MECHANICAL/ENVIRONMENTAL
Dimensions and Weight:
Transducer: 5"H x 1.5"D .33lbs
Controller: 12"H x 4.5"W x 4.0"D, 25 lbs Enclosure NEMA 13 Rated
Industrial Air Hood: 11"H x 4.5"W x 4.0"D 5 lbs
Air Fan/Filter: 110V, 15"H x 14"W x 15"D 20 lbs
Temperature: Operating -20 to +50 C
Noise Immunity:
Acoustic: Filtered to eliminate noise spectrum of common industrial environments
Electrical: Shielded for RF/EMI
Humidity: 95% maximum Non-condensing
Transducer to Controller Separation:
Standard: 10'-30' Optional: 500'
PROGRAMMABLE TRANSDUCER CONTROLLER
Display: 5 digit LED display on controller
Programming: 2 momentary push button switches on controller provide local programming of parameters. Controller can also be programmed remotely via the RS-232C, RS-422A interface
Signal Compensation: Continuous automatic calibration for temperature changes
Sample Averaging: Programmable from 1 to 4095 samples per measurement
Amplitude Filter: Programmable to filter measurements from vibrating or poorly aligned targets
Run Mode: Programmable for free running or sample on command by switch or contact closure
Relay Configuration: Programmable relay closure in or out of limit set points. Electromechanical SPDT rated 2A maximum, 60 VDC
Relay Thickness Limit Set Points: Programmable high and low relay limit set points for selectable closure, normally-in or normally-out of limits in 0.01 inch increments
Delay to Relay Closure: Programmable relay delay from 0.002 to 65 seconds in 0.002 second increments
Relay Closure Interval: Programmable relay closure interval from 0.002 to 65 seconds in 0.002 second increments